Today I received the replacement hard drives for the
two that
failed the other week.
Despite me not ticking the box (or paying the $10 for the upgrade), they
gave me 500Gb drives to replace the 400Gb drives that I'd shipped them. I
was a little dismayed to find that they were labelled as refurbished drives
though. Oh well.
I plugged the first drive in, and it started exhibiting the same behaviour
as the one that had failed, and I immediately thought "oh, they've shipped
me a dud refurbished drive". So I tried the other one. It also did the same
thing. I started to smell a rat.
I have a slightly convoluted power setup for these four disks. They're all
connected to
minotaur via IDE-USB adapters, and they have external
DC power supplies. They're just sitting on top of
minotaur, which
is a Pentium III 1-RU server, in the bottom of my linen cupboard. In order
to reduce the number of plugs involved, I have an IEC Y-cable, which goes to
two of these DC power supplies (which take an IEC cable in one end and has a
Molex connector on the other end), and the Molex cable from the DC power
supply has a Molex splitter cable on it. So I'm powering two drives from
each DC power supply, and each DC power supply is connected to an IEC
Y-cable.
There's no redundancy whatsoever, and I'm not that concerned. I don't have a
UPS anyway, and the whole thing has worked fine for months, and it reduces
the rats nest of cables a little bit, which is good. I already have way too
many things plugged into my linen cupboard.
Anyway, so after both new drives appeared to be faulty, I discovered that
both drives that had failed within a day of each other were connected to the
same DC power supply.
The plot thickened.
So I dug out a standalone IDE-USB hard drive enclosure (with a separate
power supply) and tried that. Everything worked. I tried it with just the
enclosure's power supply and either of the IDE-USB adapters I'd been using
previously. Everything worked. So I'd managed to narrow it down to the
power supply. Most unusual.
So fortunately I have four of these DC power supplies, as they came with the
IDE-USB adapters, and I freed up two of them when I went for the
aforementioned crazy power splitting setup, so I dug out one of the two
spares, and tried that, and everything worked. So I've no idea why the power
supply decided to go dicky after months of working. I've yet to introduce my
multimeter to it to try and work out what's going on.
I'm a bit embarrassed that I didn't do more homework before I declared the
drives to be faulty. To be honest, they were clicking and generally looking
"failed", and I've had a
lot going on lately, so I
just jumped to the conclusion. Oh well, at least I still haven't lost any
data. Too bad I have 200 Gb that is going to go to waste.